Failure-triggered
Heating and hot water generally move to efficient electric replacements when an existing system fails beyond repair from 1 March 2027. Existing minimum supply requirements still apply now.
Screen a Victorian residential rental portfolio against six upcoming minimum energy standards. Separate tenancy and appliance-failure triggers, evidence gaps and possible exemptions before commissioning work.
Based on Consumer Affairs Victoria's published minimum energy standards and exemptions. Ruleset dated 24 November 2026. Check source changes before relying on results.
Prepare one row per property. Upload stays in this browser; BecSpec does not send property addresses or spreadsheet contents to a server. Use a synthetic example to see the output first.
| Property | Standard | Screen result | Reason and next evidence |
|---|
“Evidence supplied” and “Exception recorded” mean a document reference or supporting data was entered; the underlying document has not been checked by BecSpec. All six outcomes are included in the export, with the ruleset version and assessment date.
Heating and hot water generally move to efficient electric replacements when an existing system fails beyond repair from 1 March 2027. Existing minimum supply requirements still apply now.
Cooling, showerheads and ceiling insulation apply to new/periodic agreements from 1 March 2027; draughtproofing starts 1 July 2027.
From 1 July 2030, cooling obligations no longer depend on the lease start. Working pre-2027 fixed cooling may qualify for a documented exception.
The template distinguishes a lease event date from the current lease start, and distinguishes a working appliance from a documented beyond-repair failure. Record exact model identity, climate-specific GEMS ratings, evidence references, 4-star WELS evidence for every shower, ceiling coverage and qualified installation evidence.
GEMS Hot/Average/Cold climate areas are not interchangeable with CER hot-water STC zones or NatHERS zones. This release does not map postcodes to GEMS climate areas or automatically check GEMS, CER or VEU product registers. Numerical equipment ratings and NCC claims therefore require separate dated evidence and are only reported in the screen, not independently verified.
For any gas appliance, draughtproofing needs a licensed gas safety check less than six months before work. Open- or flueless gas appliances can make sealing unsafe. The tool will route such cases to review rather than advise sealing.
Data handling: files are processed in memory in the browser. Do not upload a manager's real tenant names or sensitive personal information. Generated exports remain on your device. Standard website analytics should not receive spreadsheet content.
Check a heat-pump hot-water model → · Review air-conditioner model evidence →
Source: CAV property-manager guide (June 2026) · CAV exception schedule (26 October 2026). Regulatory changes, individual circumstances and all evidence should be checked before work or legal reliance.